Search found 10 matches

by chappy
January 9th, 2015, 8:04 pm
Forum: iRobot Roomba and Scooba Chat
Topic: Scooba 450 not laying down water
Replies: 17
Views: 7911

Re: Scooba 450 not laying down water

Thanks for the response vic7767. I can't seem to find the "Built in Test mode" procedure for the Scooba 450. Where would I find it?
by chappy
January 9th, 2015, 3:37 am
Forum: iRobot Roomba and Scooba Chat
Topic: Scooba 450 not laying down water
Replies: 17
Views: 7911

Scooba 450 not laying down water

I have a brand new Scooba 450 that runs a full 40 minute cycle but doesn't lay down any water. After the cycle, the clean tank is full and the empty tank empty. I have updated to the latest firmware as well as checked the three connector pins. Everything looks in order. Is there anything else I can ...
by chappy
May 21st, 2014, 1:24 am
Forum: iRobot Looj Chat
Topic: Looj Power Supply
Replies: 1
Views: 16692

Looj Power Supply

Hi All

Does anyone know if the power supply for the Looj is 110V-240V or is it just 110V for USA? Any pictures would be much appreciated.

Thanks.
by chappy
August 31st, 2010, 3:34 am
Forum: Robotic Hacking
Topic: Verro 100 Pool Cleaner for use in Australia
Replies: 2
Views: 1574

Re: Verro 100 Pool Cleaner for use in Australia

Hi mfortuna Unfortunately it is quite different to the power supply found in the Scooba and Roomba. It is an external brick but quite large. I can't find the specs for the power supply so am not sure what it can be replaced with. If I can find those details then I may be able to find a step down tra...
by chappy
August 25th, 2010, 10:34 pm
Forum: iRobot Braava - Evolution Robotics
Topic: Received My Mint
Replies: 61
Views: 22407

Re: Received My Mint

Hi Kazy

Thanks for the review of the mint. Do you know if this unit has a power supply that supports 220v/240v? Maybe you can post a picture of the power supply with details?

Many thanks.
by chappy
August 25th, 2010, 2:11 am
Forum: Robotic Hacking
Topic: Verro 100 Pool Cleaner for use in Australia
Replies: 2
Views: 1574

Verro 100 Pool Cleaner for use in Australia

Hi All

I have managed to get hold of a Verro 100 pool cleaner but have noticed it is only for use on 110v. Is there a way to modify the power supply to work on 240v Australian Power? Any ideas would be much appreciated.

Many thanks,
Chappy
by chappy
March 4th, 2009, 5:31 am
Forum: Robotic Hacking
Topic: Mod for new Scooba Power Supply - 240v
Replies: 112
Views: 71074

Re: Mod for new Scooba Power Supply - 240v

Hi Guys. I just noticed that the component 1200P60 is the same one as used on the Roomba 500. The charging circuitry looks very similar. There is a picture of the 500 series PSU at:
http://www.robotreviews.com/chat/viewtopic.php?t=6603
by chappy
March 4th, 2009, 12:59 am
Forum: Robotic Hacking
Topic: Mod for new Scooba Power Supply - 240v
Replies: 112
Views: 71074

Re: Mod for new Scooba Power Supply - 240v

Thanks Gordon. I won't try and do any modding on those power supplies until someone has investigated this fully. I am a qualified Electrical Engineer however the last time I worked on circuit boards was way back in university which means I have forgotton almost everything :) I noticed that the model...
by chappy
March 3rd, 2009, 6:14 pm
Forum: Robotic Hacking
Topic: Mod for new Scooba Power Supply - 240v
Replies: 112
Views: 71074

Re: Mod for new Scooba Power Supply - 240v

Hi Gordon. Thanks for the prompt response. D1 thru D4 are still 1N4007. The TOP246YN has been changed to another switcher which is the 1200P60. When you say use one 47u cap do you mean a 47uf 400v cap? I do you some more unmodified power supplies which I can try. I was just a bit worried about blowi...
by chappy
March 3rd, 2009, 1:50 am
Forum: Robotic Hacking
Topic: Mod for new Scooba Power Supply - 240v
Replies: 112
Views: 71074

Mod for new Scooba Power Supply - 240v

I have modded quite a few Roomba and Scooba power supplies without any issues. I have noticed that iRobot have now changed the pcb for the Scooba Power Supply. In the old power supplies I used to change the 100uf 200v capacitor to a 400v 100uf. They are now using 2 * 200v 47uf capacitors in parralel...